Interface / KP-232
SerialinterfaceKP232canbeusedasanalternativetocontrolunitKP500.Thisconnectionenables
parameterisation, monitoring, setting management, inverter control and even commissioning from a
PC or laptop computer. The serial point-to-point connection between inverter and PC complies with
specifications for transmission between data terminals (DTE) and data communication equipment
(DCE), requiring, in this mode, a serial pin-to-pin cable with DB9 male connector on the inverter side.
TheKP232interfaceiscompatiblewithlinesnolongerthan15metres.Theserialtransmissionprotocol
ensures high data security and does not require handshake signals between computer and inverter.
The VPlus software application can be supplied as an accessory. This program, which runs in Windows,
is dedicated to the complete management of the ACTIVE inverter from a PC, including the functions
ofcommissioningandparameterisation,whichcallsforthepresenceofhardwareinterfaceKP232,
CM232 or CM485. The VPlus package also includes a digital Oscilloscope Function. The oscilloscope has
four traces configurable for inverter monitoring also with graphic capabilities.
Technical data
Baud rate (kBaud) Up to 115.2 kb
Active
Plug-In
RS232 line
PC/Notebook
KP232